Overhead Fire Door Inspections

An annual rolling fire door inspection and drop test is required to ensure that your fire doors will close automatically in the case of a fire emergency.
Overhead fire door inspections. College universities physical plants residence hall delivery areas etc. Inspect rollers for damage wear 5. Inspect door for level door should not be visually crooked 3. Inspect hinges center and end hinges for damage loose fasteners 4.
Some of the facilities where overhead rolling doors are most often found include. A 1 1 see annex k for general information about fire doors. Fire rated service door model 631 is a smaller fire door with ul ulc ratings. 1 1 1 with the exception of fabric fire safety curtain assemblies this standard addresses assemblies that have.
This includes a full array of services from design install repair service and inspection. Annual fire door inspections were introduced with the adoption of the 2007 edition of nfpa 80. Nfpa standards require building owners and managers to have their rolling and sliding fire doors inspected and tested annually and to maintain written documentation of such inspections. The newest standard requires that fire rated doors be tested for functionality no less than annually and that a written record of the inspection be kept on file for the authority having jurisdiction ahj.
Our overhead door fire door drop test program helps building owners and managers stay in compliance with the most recent nfpa 80 standards while maintaining the proper operation and full closure of your facility s rolling and sliding fire doors. Overhead fire protection inc. Per the code 12 4 6 6 3 1 acceptance testing of window and fire door assemblies shall be performed by a qualified person with knowledge and understanding of the operating components of the. Florida fire door llc florida fire prevention code the 2017 edition of florida nfpa 101 requires that fire doors are inspected no less than annually.
Fire sentinel time delay release device firelite vision lites smoke detectors horns. This standard regulates the installation and maintenance of assemblies and devices used to protect openings in walls floors and ceilings against the spread of fire and smoke within into or out of buildings. Fireking model 631. Provides services within the fire sprinkler industry.
The fireking model 631 rolling fire rated service door offers superior protection wherever a small ul listed fire door is required. We cover the entire nevada and northern california regions. Inspect door sections for damage 2. Additional safety and protection features are available including.